Spécifications du fabricant:
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])

Accuracy Specifications
Function Range Resolution Accuracy
AC Volts1 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC Volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3
 
 

 

 
Resistance 
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance3 50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
 
 

 

 
AC Current
(40 Hz to 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC Current 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3


1.All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
2.Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3.Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
4.All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.

Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC Volts 600 V 1 >10 MΩ <100 pF2 >60 dB at dc,
50 Hz or 60 Hz −
AC Millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz −
DC Volts 600 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz
1.6 x 105 V Hz Max
2.For mV (AC), input impedance is approximately 1 MΩ.


General Specifications
Maximum Voltage Between any Terminal and Earth Ground 600 V
Display (LCD) 6000 counts, updates 3/sec
Battery Type 2 AAA, NEDA 24A, IEC LR03
Battery Life 200 hours minimum
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative Humidity
Operating Humidity Non-condensing when <10°C
≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse Protection for Current Inputs 11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL) 142 mm x 69 mm x 28mm
Weight 200 g
IP Rating IEC 60529: IP 40
Safety IEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic Environment IEC 61326-1: Portable
Electromagnetic Compatibility Applies to use the Korea only.  Class A Equipment (Industrial Broadcasting and Communication Equipment)1


1.This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.




Donnez votre avis

Dites-nous ce que vous pensez de cet article et partagez vos opinions avec d'autres personnes. S'il vous plaît vous assurer que votre avis ne porte que sur ce point. Tous les commentaires sont modérés et seront réexaminées dans un délai de deux jours ouvrables. commentaires inappropriés ne seront pas affichés.

Après questions-vente et questions: Contactez notre Service Clientèle. (Un représentant clientèle vous contactera pour vous).

S'il vous plaît Inscrivez-vous en premier si vous voulez plus tard modifier ou gérer les commentaires transféré par vous-même.

* Classment:
    Sélectionner les étoiles de la classification svp.
* Votre prénom et nom:
* Votre adresse e-mail:
* Title de votre avis:
* Afficher les avis: