DSO3064A KIT7 VII 4in1 Automobile Diagnostic Oscilloscope Generator Spectrum

Numéro de l'article:DSO3064A
L'article se trouve a Londres .La livraison pour la France dura ca 7-9 jours ouvrables, 3 ans Garantie, manuel en l'anglais.
Nous parlons francais
Achat immédiat: €549.00   Livraison gratuite
Quatité :
         Sous Total: €549.00
Ajouter au panier
Spécifications du fabricant:
2.Standard Accessories
 
 
 
 
 
 

 

 

Optional Accessories:

 
                 Optional Power(HT310)
LAN Module(HT312)
 
    6-Way Universal Breakout Leads(HT306)
    Auto High-Pressure Ignition Probe( HT25)
20:1 Attenuator (HT201)
 
 Acupuncture Probe Set (HT307)
Test leads(HT30A)
  
Coil-on-Plug extension leads(HT308)
Break Out Leads(HT301)
   
            AC/DC Current Clamp (CC-65)
AC/DC Current Clamp( CC-650)
          AC/DC Current Clamp( CC-1100)
Multimeter Probes(HT19)
        Large Dolphin/Gator Clips (HT18A)

4.Other Pictures:
 
 
 
 
 
 
 
 
 
 


5. Characteristic

Four-in-one Pc Based Laboratories: Oscilloscope/Arbitrary Waveform Generator/ Spectrum Analysis/Frequency Counter

Oscilloscope:
4 Channel and EXT trigger, 60MHz Bandwidth.
200MSa/s real-time sampling rate,10k—16M memory depth per Channel.
Arbitrary Waveform Generator:
25MHz arbitrary waveform output,(sine wave can deliver up to 75MHz) 200MSa/s DDS,12bits of vertical resolution.

Frequency Counter,FFT spectrum analysis.
8--36V Wide range of input voltage,suitable for vehicle power test.
USB 2.0 interface plug and play, LAN and WIFI optional.
More than 20 kinds of automatic measurement function,PASS/FAIL Check function, is suitable for engineering application.
Excellent industrial design, similar interface with bench oscilloscope ,Easy to use.
Software support : Windows NT, Windows 2000, Windows XP ,VISTA,Windows 7 ,
Supply DEMO code (VC,VB,LABVIEW) and technical support.


6. Hardware Specification

SPECIFICATIONS

DSO3064A

Oscilloscope Mode

VERTICAL

Analog Channels

4

Bandwidth

60MHz(-3dB)

Rise Time

5.8ns

Input Impedance

Resistance: 1MΩ  ; Capacitance: 25 pF

Input Sensitivity

10mV/div to 5V/div

Input Coupling

AC/DC/GND

Vertical Resolution

8 bits

Memory Depth

10K-16M/CH

Maximum Input

400V (DC+AC Peak)

HORIZONTAL

Real-Time Sampling Rate

200MS/s

Time Base Range

5ns/div to 1000s/div(1-2-5 sequences)

Time Base Precision

±50ppm

TRIGGER

Source

CH1, CH2,CH3,CH4,EXT

Mode

Edge,Pulse,Viedo,Alternative

X-Y MODE

X-Axis Input

CH1

Y-Axis Input

CH2

Phrase Shift

Max.3 degree

CURSORS AND MEASUREMENT

Voltage Measurement

Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot

Time Measurement

Frequency,Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle

Cursors Measurement

Horizontal ,Vertical, Track, Auto Measure Modes

Waveform Signal Process

+,- , x,÷, FFT, Invert

AUTO SET

 

yes

VOLTAGE RANGE

 

10mV to 5V/div @ x 1 probe

100mV to 50V/div @ x 10 probe

1V to 500V/div @ x 100 probe

10V to 5000V/div @ x 1000 probe

100V to 50000V/div @ x 10000 probe

200mV to 100V/div @ 20:1

CURRENT RANGE

 

CC65(20A),CC65(60A),CC650,CC1100

CURSOR

 

Time/frequency difference, voltage difference

FFT

 

Rectangular,Hanning,Hamming,Blackman Window

MATH

 

Adition,subtraction,multiplication,division



Arbtrory Wave Form Generator Mode

Waveform Frequency

DC~25MHz

DAC

2K~200MHz adjustable

Frequency Resolution

0.1%

Channel

1CH waveform output

Waveform Depth

4KSa

Vertical Resolution

12 bit

Frequency Stability

<30ppm

Wave Amplitude

±3.5V Max.

Output Impedance

50 Ω

Output Current

50mA Ipeak=50mA

System BW

25M

Harmonic Distortion

-50dBc(1KHz),  -40dBc(10KHz)

INTERFACE

 

USB  2.0(Lan ,WIFI Optional)

POWER SOURCE

 

8--36V Wide range of input voltage,suitable for vehicle power test

MECHANICS

Volume

255 x 190 x 45 (mm)

Weight

1Kg



7.Software:
Operating system: Windows 2000, Windows XP ,VISTA,Windows 7

8. Second Design:
Supply DEMO code (VC、VB、LABVIEW) and technical support.


package includes:
Packing :Hard Plastic Case
1pcs DSO3064A Four-in-one Pc Based Laboratories: Oscilloscope/Arbitrary Waveform Generator/ Spectrum Analysis/Frequency Counter

1pc x PP-80 Oscilloscope
4pcs x HT30A, Auto Test Cable
4pcs x HT25,Auto High-pressure Ignition Probe
4pcs x HT201, 20:1 Attenuator
4pcs x HT18A, Large Dolphin/Gator Clip
4pcs x HT19, Multimeter Probe
1pc x HT307,Acupuncture Probe Set
4pcs X HT308,Coil-on-Plug Extension Cord (with grounding cord)
1pcs x HT310, Auto Power Adapter
1pc x CC-65, AC/DC Current Clamp CC-65A
1PC X CC-650,AC/DC Current Clamp CC-650A
1PC X HT301 Break Out Leads



Donnez votre avis

Dites-nous ce que vous pensez de cet article et partagez vos opinions avec d'autres personnes. S'il vous plaît vous assurer que votre avis ne porte que sur ce point. Tous les commentaires sont modérés et seront réexaminées dans un délai de deux jours ouvrables. commentaires inappropriés ne seront pas affichés.

Après questions-vente et questions: Contactez notre Service Clientèle. (Un représentant clientèle vous contactera pour vous).

S'il vous plaît Inscrivez-vous en premier si vous voulez plus tard modifier ou gérer les commentaires transféré par vous-même.

* Classment:
    Sélectionner les étoiles de la classification svp.
* Votre prénom et nom:
* Votre adresse e-mail:
* Title de votre avis:
* Afficher les avis: