Dental Fiber Optic High Fast Speed Turbine Handpiece Skysea Fit KaVo Coupler
Product introduction:
Dental Fiber Optic High Speed turbine handpiece
Modern clipper-built design and elegant appearance
Durable.fastidiously request for design,technology and materials.
Comfortable handle.slide-proof,comfortable to hold and easy to clean.
Burs would be easily changed with the push-button.
Because of Fiber Optic Offering a better eyeshot and angle,improving your efficiency.
High density cartridge,with high cutting efficiency but less vibration and noise.
Both handpiece and quick coupling are autoclavable.Suitable for disinfection of high-temperature steam under 135℃ ,conform to clinical requirement.
Should be used by dentists to diagnose,cure and operate on patients' teeth.

Technical data:
operating pressure------- 2.2Mpa-2.5Mpa
rotate speed---------------300000-350000r/min
clamping means of bur -- Push button

applicable bur ------------ ISO1797-1type3 1.59-1.60mm
Means for sterilizing------ prevacuumizing,autoclave <135℃
couplers ------------------ Quick coupler 360 degree swivel
spray --------------------- Triple Water Port Spray
HEAD HIGHT ------------- 14.00mm

NOTICE IN USING HIGH SPEED HANDPIECE
l Prior to each use of handpiece, all instruments must be inspected for proper operation。
l Before each use of handpiece, make sure that the air supply pressure and the water supply pressure are suitable for the operation. (Please consult the requirements of air pressure and water pressure mentioned on the operation manual). Our standard head high speed handpiece will reach the rotation speed 40000r/min and work perfectly if the air pressure at the end of the handpeices is 2.2KGF/CM2. Bearings would be damaged if air pressure is over 2.2KGF/CM2。


l Please make sure that the air source and water source are clean. There will be stem in the spray holes or in the cartridges, which will affect the quality of the handpiece and will shorten the lifespan of the bearings due to the abnormal friction。

lOnly use standard burs from normal manufacturers with a shaft diameter of 1.59~1.60 mm, and a max. total length of 26mm (1.02”); (Mini head handpiece should use short burs with the same shaft diameter). Do not use bent, worn, damaged or unclean burs。


lDo not extend burs outward from handpiece head. Burs must be inserted all the way into chuck for proper bur retention. Otherwise, the cartridge will be damaged, or personal injury will be caused due to bur ejection。


lEach handpeice need to replace with another one when it is under operation over 2 hours。


lClean and lubricate the handpiece with good quality oil spray after each use and/or before autoclaving. Lubricant is strongly recommended。
Donnez votre avis

Dites-nous ce que vous pensez de cet article et partagez vos opinions avec d'autres personnes. S'il vous plaît vous assurer que votre avis ne porte que sur ce point. Tous les commentaires sont modérés et seront réexaminées dans un délai de deux jours ouvrables. commentaires inappropriés ne seront pas affichés.

Après questions-vente et questions: Contactez notre Service Clientèle. (Un représentant clientèle vous contactera pour vous).

S'il vous plaît Inscrivez-vous en premier si vous voulez plus tard modifier ou gérer les commentaires transféré par vous-même.

* Classment:
    Sélectionner les étoiles de la classification svp.
* Votre prénom et nom:
* Votre adresse e-mail:
* Title de votre avis:
* Afficher les avis: